Plasma-Material Interaction Data Set 164

Permeation of D in Cr2O3

$$ P = P_0 \exp\left(-\frac{E_\mathrm{p}}{k_\mathrm{B}T}\right) $$

[In the above formula, the Boltzmann constant is expressed in \(\mathrm{eV\,K^{-1}}\).]

Comment

120nm composite seen to decrease permeability up to a certain Cr2O3 thickness (80nm). Self-made apparatus that had a permeation chamber and vacuum.

Download JSON

  1. B96: Y. Wu, S. Wang, S. Li, D. He, X. Liu, L. Jiang, H. Huang, "Deuterium permeation properties of Er2O3/Cr2O3 composite coating prepared by MOCVD on 316L stainless steel ", Fusion Engineering and Design 113, 205-210 (2016). [10.1016/j.fusengdes.2016.09.007]