{"id":126,"qualified_id":"DM126","process":"Permeation","process_types":[{"abbreviation":"MPM","description":"Permeation"}],"method":"Experiment","scaled":false,"material":"Cu-Al2O3","alloy":"Glidcop (Al25)","species":{"qualified_id":"F3","text":"H","charge":0},"comment":"ODS. Fitting expression for flux vs temperature for permeability. Pressure dependence of permeability: ~p^0.53. Data provided by M. Lavrentiev (UKAEA, 2024) with permission from STEP.","refs":[{"qualified_id":"B104","authors":"G. Esteban, G. Alberro, I. Peñalva, A. Peña, F. Legarda, B. Riccardi","title":"Hydrogen transport and trapping in the GlidCop Al25 IG alloy","journal":"Fusion Engineering and Design","volume":"84","page_start":"757","page_end":"761","year":2009,"doi":"10.1016/j.fusengdes.2008.12.007","bibcode":"2009FusED..84..757E","url":"https://dx.doi.org/10.1016/j.fusengdes.2008.12.007"}],"json_data":{"P0":{"value":5.87e-07,"units":"mol.m-1.s-1.Pa-1/2"},"Ep":{"value":0.84,"units":"eV"},"Trange":[573,793]}}