Process | HIN: Ionization |
Data type | cross section | uploaded on 2023-02-08 |
Comment | Fit function taken from p110. Error: E<2keV/u -> 100%, 2keV/u<E<10keV/u -> 40%, 10keV/u<E<100keV/u -> 30%, E<100keV/u -> 20% |
Method | semi-empirical |
Frame | Target |
Columns |
|
Ref |
|
Data | Download (data from fit) |
Fit Function Details |
\[\sigma_{ion}^{1,2,3}(E) =10^{-16}A_1 \Bigg[\frac{e^{-\frac{A_2}{E}}\ln(1+A_3E)}{E} + \frac{A_4e^{-A_5E}}{E^{A_6} + A_7E^{A_8}}\Bigg]\] | ||||||||||||||||
Python | def h_hin_javen_he(E, A1, A2, A3, A4, A5, A6, A7, A8): """ This function calculates He+2 impact ionzation cross sections (in cm2) of H n=1,2 and 3. param E: requested impact energy in keV/u type E: float, np.ndarray param Ai: fit coefficient type Ai: float """ sigma = 1e-16 * A1 * (np.exp(-A2/E) * np.log(1 + A3*E) / E + A4*np.exp(-A5*E)/ (E**A6 + A7*E**A8)) return sigma |
||||||||||||||||
Fit Precision | 3.8 % | ||||||||||||||||
Fit Coefficients |
|
||||||||||||||||
x-range | – |