DataSet D8052

\[\mathrm{e}^- + \mathrm{H} \; n=2 \rightarrow \mathrm{H}^{+} + 2\mathrm{e}^-\]


Process EIN: Ionization
Data type cross section | uploaded on 2022-07-21
comment Reaction 1.2.4

Methodsemi-empirical
Columns
  1. E /eV
  2. sigma /cm2
Uncertainty50 %
Ref
DataDownload (data from fit)

Fitted Data

Fit Function
Details
\[\begin{align*} \sigma = \frac{10^{-13}}{ion\ \ pe}\Bigg[a \; \ln\left(\frac{pe}{ion}\right) + \sum_{i=istart}^{iend} pcf(i) \left(1- \frac{ion}{pe}\right)^{i- istart +1}\Bigg] \\ \begin{cases} ion = pcf(9);\; a = pcf (10); \; istart =11;\; iend =kncf & \text{if } kncf \gt 7 \; \text{and}\; pe \gt pcf(8) \\ ion = pcf(1); \; a = pcf (2); \; istart =3;\ iend =7& \text{if } kncf \gt 7 \; \text{and}\; pe \lt pcf(8) \\ ion = pcf(1); \; a = pcf (2); \; istart =3;\ iend =kncf& \text{if } kncf \le 7 \\ \end{cases} \end{align*}\]
Python MISSING FIT FUNCTION
Fortran
c
c###################################################################
c
      subroutine albeli(pe, pcf, kncf, pxs, kermsg)
c
c     electron impact ionization cross section fits
c
c     reference: k. l. bell et al, j. phys. chem. ref. data 12, 891
c                (1983)
c
c     this is an iaea subroutine to calculate cross sections for
c     projectile energy (ev).
c
c     pe =  electron energy (ev)
c
c     the number of fitting parameters varies depending on the
c     number of terms taken in the numerical fitting and on the
c     allowance for excitation autoionization in the cross section
c     to fit cross sections with excitation autoionization two seperate
c     fits are defined. one from the ionization threshold and a second
c     fit for energies above the autoionization threshold.
c     the number of parameters in any entry is given by kncf
c
c     pcf(1) = ionization potential (ev)
c     pcf(2-7) = fitting parameters ( can be less than 6 parameters)
c
c     if cross section has excitation autoionization structure then
c     for the second fit
c
c     pcf(8) = autoionization threshold (ev)
c     pcf(9) = ionization potential (ev)
c     pcf(10-15) = fitting parameters for this fit (can be less than
c                  6 parameters)
c
c     kncf = number of parameters supplied in pcf (must be 8)
c     pxs = ionization cross section (cm[2])
c     kermsg = error message, ' ' is ok
c
c     written by j. j. smith , iaea atomic and molecular data unit
c
c======================================================================
c
      double precision pe, pcf, pxs
      double precision ion, power, power1, xs, a, x, x2
      dimension pcf(15)
      character*(*) kermsg
c
      kermsg = ' '
      if(pe .lt. pcf(1)) then
        pxs = 0.0d0
        return
      else
        kermsg = ' '
      endif
c
c---  determine parameters to be used
c
      if (kncf .gt. 7 .and. pe .gt. pcf(8) ) then
c
c---      autoionization included and energy > autoionization threshold
c
        ion = pcf(9)
        a=pcf(10)
        istart=11
        iend=kncf
      else
        ion = pcf(1)
        a=pcf(2)
        istart=3
        if (kncf .gt. 7) then
          iend=7
        else
          iend = kncf
        endif
      endif
c
c---  generate cross section
c
      x=ion/pe
      x2= 1.0d0/x
c
c---  contribution from bethe term
c
      xs = a*dlog(x2)
      if ( kncf .ge. istart) then
c
c---  contribution from least squares fit terms
c
        power1 = 1.0d0 - x
        power = power1
        do 10 i=istart,iend
          xs = xs + pcf(i)*power
          power = power*power1
  10    continue
      endif
c
c---  scale results to cm[2]
c
      pxs= 1.0d-13*xs /(pe*ion)
c
      return
      end
Fit Coefficients
pcf(1)
 3.400e+00
pcf(2)
 1.478e-01
pcf(3)
 8.087e-03
pcf(4)
-6.227e-02
pcf(5)
 1.941e+00
pcf(6)
-2.198e+00
pcf(7)
 9.589e-01
kncf
 7.000e+00
x-range 3.4 – 20000.0